Pump: Difference between revisions
Mefisto1029 (talk | contribs) |
GoatWizard (talk | contribs) |
||
Line 13: | Line 13: | ||
== Throughput == | == Throughput == | ||
Pumps can move | Pumps can move 20 units of fluid per tick, or 1200 per second. This is further limited by the input fluid container: the pump can never move more fluid than is available and it is therefore generally beneficial to have a pressurized [[storage tank]] directly at its input. More information on pump and pipe throughput can be found on [[Fluid_system#Pipelines|fluid system]]. | ||
== Loading/unloading fluid wagons == | == Loading/unloading fluid wagons == |
Latest revision as of 11:09, 23 October 2024
Pump |
Recipe |
|||||||||||||
+ + + → | |||||||||||||
Total raw |
|||||||||||||
+ + + | |||||||||||||
Map color |
|||||||||||||
Fluid storage volume |
400 |
||||||||||||
Health |
|
||||||||||||
Resistances |
Fire: 0/80% |
||||||||||||
Stack size |
50 |
||||||||||||
50 (1 stack) |
|||||||||||||
Dimensions |
1×2 |
||||||||||||
Energy consumption |
30 kW (electric) |
||||||||||||
Pumping speed |
|
||||||||||||
Mining time |
0.2 |
||||||||||||
Prototype type |
|||||||||||||
Internal name |
pump |
||||||||||||
Required technologies |
|||||||||||||
Produced by |
|||||||||||||
This article is about the pump, formerly known as the small pump. For the water extraction device, see offshore pump. For the oil extraction device, see pumpjack.
Overview
A Pump is a multipurpose fluid handling device which can be used to move fluids, perform flow control, prevent back-flow and load/unload trains. The pump can be seen as the inserter for fluids.
When connected to pipes on both ends of the pump and powered, the pump will transfer fluid from the source side to the output side if it will fit. This will occur even if the input side has significantly lower fluid levels.
Furthermore, unlike normal pipes, pumps can connect to pipes only on the front and back of the pump instead of connecting to pipes from all sides. This can be useful for having tightly packed lines of pipes being parallel to each other, without the risk of fluids mixing, acting as a "diode" pipe.
Throughput
Pumps can move 20 units of fluid per tick, or 1200 per second. This is further limited by the input fluid container: the pump can never move more fluid than is available and it is therefore generally beneficial to have a pressurized storage tank directly at its input. More information on pump and pipe throughput can be found on fluid system.
Loading/unloading fluid wagons
Pumps can load and unload fluid wagons at train stops. When a pump is placed with one end facing a rail track and the other end connected to a pipe, it will visually change. When a fluid wagon is stopped adjacent, the pump head will connect to the top of the nearest tank and begin transferring fluids. It will not connect if a circuit condition is preventing it, or it is unpowered.
Use as a valve
The pump works as a controllable valve:
- When powered, the pump will let fluids through, but only in its set direction.
- If unpowered, the pump doesn't let anything through.
- If the pump is powered but has a circuit condition, it will only let fluids through when the condition is met.
Animations and visuals
History
- 2.0.7:
- Lowered Fluid pumping speed from 12000 to 1200.
- 0.15.0:
- Graphics changed, now has a nice animation
- Size changed to 2×1 tiles
- Recipe changed, now requires engine units rather than electric engine units.
- Throughput massively increased.
- Renamed from Small Pump to Pump
- 0.12.1:
- Copy pasting settings now works for small pumps.
- 0.12.0:
- Now connectible to the circuit network.
- 0.10.0:
- Changed collision box logic
- 0.9.0:
- Introduced