In other languages: Čeština Deutsch Français 日本語 한국어 Polski Русский Українська 简体中文

Pump: Difference between revisions

From Official Factorio Wiki
Jump to navigation Jump to search
(→‎Overview: liquids -> fluids (includes gases e.g. petroleum gas, steam))
m (generalize again)
Line 13: Line 13:
The pump works as a controllable valve:
The pump works as a controllable valve:


* When powered, the pump will let liquids through, but only in its set direction.
* When powered, the pump will let fluids through, but only in its set direction.
* If un-powered, the pump doesn't let anything through.
* If unpowered, the pump doesn't let anything through.
* If the pump is powered but has a circuit condition, it will only let fluids through when the condition is met.
* If the pump is powered but has a circuit condition, it will only let fluids through when the condition is met.<p>This can be used to control some parts of a player's factory. For example, with a single wire from a [[lubricant]] tank to a pump pumping [[heavy oil]], you can disable cracking heavy oil → [[light oil]] when lubricant is needed.
: This can be used to control some parts of a player's factory. For example, with a single wire from a [[lubricant]] tank to a pump pumping [[heavy oil]], you can disable cracking heavy oil → [[light oil]] when lubricant is needed.


An example that uses some useful properties of the pump can be found [http://www.factorioforums.com/forum/viewtopic.php?f=8&t=3724 on the forums].
An example that uses some useful properties of the pump can be found [http://www.factorioforums.com/forum/viewtopic.php?f=8&t=3724 on the forums].
Line 26: Line 25:
== Throughput ==
== Throughput ==


Pumps can move 200 units of fluid per tick, or 12000 per second. This is further limited by the input fluid container: the pump can never move more fluid than is available and it is therefore generally beneficial to have a pressurized [[storage tank]] directly at its input. More information on pump and pipe throughput can be found [https://forums.factorio.com/viewtopic.php?f=18&t=19851 on the forums]
Pumps can move 200 units of fluid per tick, or 12000 per second. This is further limited by the input fluid container: the pump can never move more fluid than is available and it is therefore generally beneficial to have a pressurized [[storage tank]] directly at its input. More information on pump and pipe throughput can be found [https://forums.factorio.com/viewtopic.php?f=18&t=19851 on the forums].


== Animations and visuals ==
== Animations and visuals ==

Revision as of 02:27, 10 August 2018

Pump.png
Pump

Pump entity anim.gif

Recipe

Time.png
2
+
Engine unit.png
1
+
Pipe.png
1
+
Steel plate.png
1
Pump.png
1

Total raw

Time.png
2.5
+
Engine unit.png
1
+
Iron plate.png
1
+
Steel plate.png
1

Map color

Fluid storage volume

400

Health

Quality normal.png 180
Quality uncommon.png 234 Quality rare.png 288
Quality epic.png 342 Quality legendary.png 450

Resistances

Fire: 0/80%
Impact: 0/30%

Stack size

50

Rocket capacity

50 (1 stack)

Dimensions

1×2

Energy consumption

30 kW (electric)

Pumping speed

Quality normal.png 1200/s
Quality uncommon.png 1560/s Quality rare.png 1920/s
Quality epic.png 2280/s Quality legendary.png 3000/s

Mining time

0.2

Prototype type

pump

Internal name

pump

Required technologies

Fluid handling (research).png

Produced by

Assembling machine 1.png
Assembling machine 2.png
Assembling machine 3.png
Player.png

This article is about the pump, formerly known as the small pump. For the water extraction device, see offshore pump. For the oil extraction device, see pumpjack.

Overview

A Pump is a multipurpose fluid handling device which can be used to move fluids, perform flow control, prevent back-flow and load/unload trains. The pump can be seen as the inserter for fluids.

When connected to pipes on both ends of the pump and powered, the pump will transfer fluid from the source side to the output side if it will fit. This will occur even if the input side has significantly lower fluid levels.

Note that the pump can't mix different kinds of fluids.

Use as a Valve

The pump works as a controllable valve:

  • When powered, the pump will let fluids through, but only in its set direction.
  • If unpowered, the pump doesn't let anything through.
  • If the pump is powered but has a circuit condition, it will only let fluids through when the condition is met.

    This can be used to control some parts of a player's factory. For example, with a single wire from a lubricant tank to a pump pumping heavy oil, you can disable cracking heavy oil → light oil when lubricant is needed.

An example that uses some useful properties of the pump can be found on the forums.

Loading/unloading fluid wagons

Pumps can load and unload fluid wagons at train stops. When a pump is placed with one end facing a rail track and the other end connected to a pipe, it will visually change. When a fluid wagon is stopped adjacent, the pump head will connect to the top of the nearest tank and begin transferring fluids. It will not connect if a circuit condition is preventing it, or it is unpowered.

Throughput

Pumps can move 200 units of fluid per tick, or 12000 per second. This is further limited by the input fluid container: the pump can never move more fluid than is available and it is therefore generally beneficial to have a pressurized storage tank directly at its input. More information on pump and pipe throughput can be found on the forums.

Animations and visuals

Pipe network animation.gif

History

  • 0.15.0:
    • Graphics changed, now has a nice animation
    • Size changed to 2×1 tiles
    • Recipe changed, now requires engine units rather than electric engine units.
    • Throughput massively increased.
    • Renamed from Small Pump to Pump
  • 0.12.1:
    • Copy pasting settings now works for small pumps.
  • 0.10.0:
    • Changed collision box logic

See also