In other languages: Čeština Deutsch Français 日本語 Polski Русский Українська 简体中文

Roboport: Difference between revisions

From Official Factorio Wiki
Jump to navigation Jump to search
(Added more info on roboports, corrected small typos.)
(Removed Trivia section because (1) it was non-trivial information and (2) the information is covered sufficiently in the "Storage" section.)
Tag: Manual revert
(35 intermediate revisions by 12 users not shown)
Line 1: Line 1:
{{Languages}}
{{Languages}}
{{Machinery
{{:Infobox:Roboport}}
|health=500
The '''roboport''' is the resting place for all [[construction robot]]s and [[logistic robot]]s. It emits an area of 50×50 tiles, in which logistic robots can interact with logistic network entities, such as [[storage chest]]s, or [[requester chest]]s. Additionally, a 110×110 tile area is created for construction robots to repair, construct or remove structures. This can be seen by hovering the mouse on a roboport, or logistics chest which is inside the logistic zone.
|supplyarea=50x50
|constructionarea=100x100
|transmission=200 kW electric
|recharge=4 x 200 kW electric
|rechargebuffer=2.0 MW electric
|input=Steel Plate, 45 + Iron Gear Wheel, 45 + Advanced Circuit, 45 + Time, 15
|raw=Iron Plate, 180 + Copper Plate, 225 + Steel Plate, 45 + Plastic bar, 90
|technologies=Construction robotics
|producers=Manual + Assembling machine 2 + Assembling machine 3
}}


The Roboport is the resting place for all [[Robots]]. It also emits an area of 50x50 tiles, in which logistic robots can interact with logistic network entities, such as [[Storage chest]]s, or [[Requester chest]]s. Additionally, a 100x100 tile area is created for construction robots to function. This can be seen by hovering the mouse on a roboport, or logistics chest.
* The smaller <span style="color:#F98A1D">orange</span> square represents the reach of the logistics network where both logistics and construction robots can move.
* The larger <span style="color:#66FF66">green</span> square represents the extent of the construction network where only construction robots can move.


* The <span style="color:#E88A0C">orange</span> square represents the reach of the logistics network where logistics robots can move.
Robots placed into the air from the [[Player|player's]] inventory inside of a roboport's coverage will seek out the nearest roboport to charge and rest.
* The <span style="color:#00FF00">green</span> square represents the extent of the construction network where construction robots can repair, construct or remove structures. Note that construction robots can function inside of the logistics square, it is not exclusive to logistics robots.  


Robots placed into the air from the player's inventory inside of a roboport's coverage will seek out the nearest roboport to charge and rest.
Two or more roboports can connect to form a [[logistic network]], if the borders of the orange logistic areas touch. This is shown by a dotted line running between the two ports. An example of this can be seen on the bottom-right. Non-connected roboports will not share robots.


Two or more roboports can connect to form a [[Robotic network|robotic network]], if the borders of the orange logistic areas touch. This is shown by a dotted line running between the two ports. An example of this can be seen on the bottom-right. Non-connected roboports will not share robots.
Players or [[spidertron]] equipped with a [[personal roboport]] or [[personal roboport MK2]] in their armor can act as a mobile roboport themselves, if they have any robots in their inventory.


[[File:roboport_connection.jpg|300x300px|thumb|Two roboports connecting to form a logistic network. Notice the yellow dotted line indicating a successful bond.]]
[[File:roboport_connection.jpg|300×300px|thumb|Two roboports connecting to form a logistic network. Notice the yellow dotted line indicating a successful bond.]]


== Storage ==
== Storage ==
A Roboport contains 7 [[Storages/Stack|slots]] reserved for [[robots]], and another 7 for [[repair pack]]s. Robots and repair packs can be inserted into the roboport with an [[inserter]]. While seemingly useful, a repair pack inside a roboport is reserved for the construction robots inside the roboport only. Repair packs are better stored inside a [[Storage Chest|logistics storage chest]] or a [[passive provider chest]] where they can be used by all robots in the logistics network. Construction bots, when provided with repair packs, will automatically repair all damaged structures inside of a roboport's coverage area.
A roboport contains 7 [[Stack|slots]] reserved for [[robots]], and another 7 for [[repair pack]]s. Robots and repair packs can be inserted into the roboport with an [[inserter]]. Furthermore, robots (but not repair packs) can be removed from the roboport with an inserter. Repair packs inside a roboport are available for all robots and requester chests inside the logistic zone of that roboport. Construction bots, when provided with repair packs, will automatically repair all damaged structures inside of a roboport's coverage area.


If a roboport is full of robots, robots attempting to rest will find a different roboport.
If a roboport is full of robots, robots attempting to rest will find a different roboport, if one is available.
 
[[File:roboport_gui.png|thumb|250px|none|Roboport GUI]]


== Power usage ==
== Power usage ==
The Roboport needs ~200 kW of energy when idle, but can use up to ~2 MW when charging bots. Ensure the power grid can meet the demand when making large requests of the robot system.
Roboports have 4 chargers, which are used to recharge the flying bots. More roboports in a small area will allow for greater charging throughput, if a lot of robots need charging. Robots waiting to be charged will float in place near the roboport and wait their turn.
Roboports have 4 chargers, which are used to recharge the flying bots. More roboports in a small area will allow for greater charging throughput, if a lot of robots need charging. Robots waiting to be charged will float in place near the roboport and wait their turn.


Robots will not enter a roboport to rest unless they have full charge. Robots with low/no charge can still fly, but will move extremely slowly.
Robots will not enter a roboport to rest unless they have full charge. Robots with low/no charge can still fly, but will move extremely slowly.
== History ==
{{history|0.16.17|
* Increased the stack size of roboport from 5 to 10.}}
{{history|0.16.0|
* Roboports now provide the repair packs they have for other robots to use.}}
{{history|0.15.6|
* Increased roboport construction range to 55 (110×110 area) to make roboports able to build each other without interconnecting their logistic areas, and not break when there are obstacles like trees or rocks.}}
{{history|0.15.0|
* Roboport construction area changed from 50 to 51 to allow roboports build/deconstruct each other even when there is a 1 tile gap between their logistic areas.}}
{{history|0.13.0|
* Roboport is connectible to the circuit network, it sends the logistic network contents or the robot statistics of the network.
* Roboports have decreased transmission power consumption (200 kW to 50 kW) while the robots and their recharging have increased power consumption (200 kW per recharge slot to 1MW per slot)
* Reduced number of drawn connections between roboports again.
* Optimized roboport radius rendering.
}}
{{history|0.12.5|
* Robots can charge from a closer roboport on their way to a more distant one.}}
{{history|0.12.0|
* Reduced number of rendered roboport connections.
* Inserters can now extract from roboports.
* Optimized adding and removing roboports, robots keep their tasks if possible.
}}
{{history|0.10.7|
* Roboport gui labels updated to state "Roboport"
* Roboport is no longer categorized as a military structure.
}}
{{history|0.10.0|
* Backer names are used to name roboports.}}
{{history|0.9.0|
* Roboports have a separate logistic radius (now 25) and construction radius (now 50)
* Area visualizations for roboports are displayed under their entities.
}}
{{history|0.8.5|
* Only repair packs may be placed into the roboport slots.}}
{{history|0.8.2|
* Roboport supply area increased from 40×40 to 50×50.}}
{{history|0.8.1|
* Lowered transmission energy consumption of roboport from 200 W to 100 W.}}
{{history|0.8.0|
* Introduced}}


== See also ==
== See also ==
* [[Robotic network]]
* [[Logistic network]]
* [[Logistic network]]
* [[Repair pack]]
* [[Repair pack]]
* [[Robots]]
* [[Robots]]
* [http://www.factorioforums.com/forum/viewtopic.php?f=18&t=6005 How exactly do RoboPorts work with each other?]
* [http://www.factorioforums.com/forum/viewtopic.php?f=6&t=7993 Splitting up roboport functions]:
** Recharge bots
** Store unused bots
** Create a construction network
** Create a logistics network
{{MachineNav}}


[[Category:Items]]
{{LogisticsNav}}
{{C|Logistic network}}
{{C|Logistic network}}
{{C|Repair}}
{{C|Robots}}

Revision as of 19:38, 13 December 2022

Roboport.png
Roboport

Roboport entity.png

Recipe

Time.png
5
+
Advanced circuit.png
45
+
Iron gear wheel.png
45
+
Steel plate.png
45
Roboport.png
1

Total raw

Time.png
455
+
Copper plate.png
225
+
Iron plate.png
180
+
Plastic bar.png
90
+
Steel plate.png
45

Map color

Health

Quality normal.png 500
Quality uncommon.png 650 Quality rare.png 800
Quality epic.png 950 Quality legendary.png 1250

Resistances

Fire: 0/60%
Impact: 0/30%

Stack size

10

Rocket capacity

10 (1 stack)

Dimensions

4×4

Energy consumption

Quality normal.png 2.1 MW
Quality uncommon.png 2.7 MW Quality rare.png 3.3 MW
Quality epic.png 3.9 MW Quality legendary.png 5.1 MW
(electric)

Drain

50 kW (electric)

Robot recharge rate

Quality normal.png 4×500 kW
Quality uncommon.png 4×650 kW Quality rare.png 4×800 kW
Quality epic.png 4×950 kW Quality legendary.png 4×1.25 MW
(electric)

Mining time

0.1

Supply area

50×50 tiles

Construction area

110×110 tiles

Prototype type

roboport

Internal name

roboport

Required technologies

Construction robotics (research).png
Logistic robotics (research).png

Produced by

Assembling machine 1.png
Assembling machine 2.png
Assembling machine 3.png
Player.png

The roboport is the resting place for all construction robots and logistic robots. It emits an area of 50×50 tiles, in which logistic robots can interact with logistic network entities, such as storage chests, or requester chests. Additionally, a 110×110 tile area is created for construction robots to repair, construct or remove structures. This can be seen by hovering the mouse on a roboport, or logistics chest which is inside the logistic zone.

  • The smaller orange square represents the reach of the logistics network where both logistics and construction robots can move.
  • The larger green square represents the extent of the construction network where only construction robots can move.

Robots placed into the air from the player's inventory inside of a roboport's coverage will seek out the nearest roboport to charge and rest.

Two or more roboports can connect to form a logistic network, if the borders of the orange logistic areas touch. This is shown by a dotted line running between the two ports. An example of this can be seen on the bottom-right. Non-connected roboports will not share robots.

Players or spidertron equipped with a personal roboport or personal roboport MK2 in their armor can act as a mobile roboport themselves, if they have any robots in their inventory.

Two roboports connecting to form a logistic network. Notice the yellow dotted line indicating a successful bond.

Storage

A roboport contains 7 slots reserved for robots, and another 7 for repair packs. Robots and repair packs can be inserted into the roboport with an inserter. Furthermore, robots (but not repair packs) can be removed from the roboport with an inserter. Repair packs inside a roboport are available for all robots and requester chests inside the logistic zone of that roboport. Construction bots, when provided with repair packs, will automatically repair all damaged structures inside of a roboport's coverage area.

If a roboport is full of robots, robots attempting to rest will find a different roboport, if one is available.

Roboport GUI

Power usage

Roboports have 4 chargers, which are used to recharge the flying bots. More roboports in a small area will allow for greater charging throughput, if a lot of robots need charging. Robots waiting to be charged will float in place near the roboport and wait their turn.

Robots will not enter a roboport to rest unless they have full charge. Robots with low/no charge can still fly, but will move extremely slowly.

History

  • 0.16.17:
    • Increased the stack size of roboport from 5 to 10.
  • 0.16.0:
    • Roboports now provide the repair packs they have for other robots to use.
  • 0.15.6:
    • Increased roboport construction range to 55 (110×110 area) to make roboports able to build each other without interconnecting their logistic areas, and not break when there are obstacles like trees or rocks.
  • 0.15.0:
    • Roboport construction area changed from 50 to 51 to allow roboports build/deconstruct each other even when there is a 1 tile gap between their logistic areas.
  • 0.13.0:
    • Roboport is connectible to the circuit network, it sends the logistic network contents or the robot statistics of the network.
    • Roboports have decreased transmission power consumption (200 kW to 50 kW) while the robots and their recharging have increased power consumption (200 kW per recharge slot to 1MW per slot)
    • Reduced number of drawn connections between roboports again.
    • Optimized roboport radius rendering.
  • 0.12.5:
    • Robots can charge from a closer roboport on their way to a more distant one.
  • 0.12.0:
    • Reduced number of rendered roboport connections.
    • Inserters can now extract from roboports.
    • Optimized adding and removing roboports, robots keep their tasks if possible.
  • 0.10.7:
    • Roboport gui labels updated to state "Roboport"
    • Roboport is no longer categorized as a military structure.
  • 0.10.0:
    • Backer names are used to name roboports.
  • 0.9.0:
    • Roboports have a separate logistic radius (now 25) and construction radius (now 50)
    • Area visualizations for roboports are displayed under their entities.
  • 0.8.5:
    • Only repair packs may be placed into the roboport slots.
  • 0.8.2:
    • Roboport supply area increased from 40×40 to 50×50.
  • 0.8.1:
    • Lowered transmission energy consumption of roboport from 200 W to 100 W.

See also