In other languages: Čeština Deutsch Français 日本語 한국어 Polski Русский Українська 简体中文

Pipe to ground: Difference between revisions

From Official Factorio Wiki
Jump to navigation Jump to search
(New navigation organization)
(Add full history)
Line 1: Line 1:
{{Languages}}
{{Languages}}
{{:Pipe to ground/infobox}}


{{:Pipe to ground/infobox}}
The pipe-to-ground is a distribution method for [[Liquid network|liquids and gases]]. Since a basic [[pipe]] is impassable, these are necessary to keep the factory open, as well as to cross resource lines.
The pipe-to-ground is a distribution method for [[Liquid network|liquids and gases]]. Since a basic [[pipe]] is impassable, these are necessary to keep the factory open, as well as to cross resource lines.


Line 7: Line 7:


== Notes ==
== Notes ==
* The maximum gap that can be spanned between one pair of ground pipes is 9 squares.
* The maximum gap that can be spanned between one pair of ground pipes is 10 squares.
* Pipe-to-ground stores less liquid than basic pipes.
* Pipe-to-ground stores less liquid than basic pipes.
* While pipe-to-ground is the developer name for the entity, the community has taken to simply referring to this entity as "underground pipe". This is the most common reference.
== History ==
{{history|0.13.0|
* Underground pipes are now automatically placed at maximum distance when building by dragging.}}
{{history|0.10.1|
* Icon changes.}}
{{history|0.9.3|
* For two different pipe to ground types, the distance limit is now the minimum of the two connections.}}
{{history|0.9.2|
* Pipe to ground can now reach up to 10 tiles underground.
* A pipe to ground can have multiple underground connections.}}
{{history|0.9.0|
* Pipe to grounds are made in pairs, and are more expensive to craft.}}
{{history|0.2.1|
* Automatic 180 degree rotation of underground pipes when the first pipe is built.}}
{{history|0.2.0|
* Visualization of the connection between two underground pipes.}}
{{history|0.1.0|
* Introduced}}


== See also ==
== See also ==

Revision as of 03:30, 15 March 2017

Pipe to ground/infobox

The pipe-to-ground is a distribution method for liquids and gases. Since a basic pipe is impassable, these are necessary to keep the factory open, as well as to cross resource lines.

Only one fluid can be inside a pipe-to-ground at one time. Trying to mix two fluids can destroy one of the fluids. Read more on liquid mechanics.

Notes

  • The maximum gap that can be spanned between one pair of ground pipes is 10 squares.
  • Pipe-to-ground stores less liquid than basic pipes.
  • While pipe-to-ground is the developer name for the entity, the community has taken to simply referring to this entity as "underground pipe". This is the most common reference.

History

  • 0.13.0:
    • Underground pipes are now automatically placed at maximum distance when building by dragging.
  • 0.9.3:
    • For two different pipe to ground types, the distance limit is now the minimum of the two connections.
  • 0.9.2:
    • Pipe to ground can now reach up to 10 tiles underground.
    • A pipe to ground can have multiple underground connections.
  • 0.9.0:
    • Pipe to grounds are made in pairs, and are more expensive to craft.
  • 0.2.1:
    • Automatic 180 degree rotation of underground pipes when the first pipe is built.
  • 0.2.0:
    • Visualization of the connection between two underground pipes.

See also