Steam turbine: Difference between revisions
m →Power output: unit fix |
Twisted Code (talk | contribs) can also be used with heating tower now. |
||
Line 1: | Line 1: | ||
{{Languages}} | {{Languages}} | ||
{{:Infobox:Steam turbine}} | {{:Infobox:Steam turbine}} | ||
The '''steam turbine''' consumes [[steam]] to create electric energy. It is usually used together with [[heat exchanger]]s and a [[nuclear reactor]]. | The '''steam turbine''' consumes [[steam]] to create electric energy. It is usually used together with [[heat exchanger]]s and a [[nuclear reactor]] or [[heating tower]]{{SA}}. | ||
While designed for the 500°C steam of a nuclear reactor, turbines can still be connected to [[boiler]]s for use in conventional 165°C steam power. At this mode, the steam turbine acts equal to two separate [[steam engine]]s, producing 1800 kW and consuming 60 steam/sec. However, actual power production is based on the temperature of the steam, not the building itself. This means that using a steam turbine is no more fuel-efficient than using two steam engines. Unless saving space within a large build, it is not necessary to use the more costly turbines for boiler steam. | While designed for the 500°C steam of a nuclear reactor, turbines can still be connected to [[boiler]]s for use in conventional 165°C steam power. At this mode, the steam turbine acts equal to two separate [[steam engine]]s, producing 1800 kW and consuming 60 steam/sec. However, actual power production is based on the temperature of the steam, not the building itself. This means that using a steam turbine is no more fuel-efficient than using two steam engines. Unless saving space within a large build, it is not necessary to use the more costly turbines for boiler steam. |
Revision as of 22:55, 4 March 2025
Steam turbine |
- Base game
- Space Age mod
The steam turbine consumes steam to create electric energy. It is usually used together with heat exchangers and a nuclear reactor or heating tower.
While designed for the 500°C steam of a nuclear reactor, turbines can still be connected to boilers for use in conventional 165°C steam power. At this mode, the steam turbine acts equal to two separate steam engines, producing 1800 kW and consuming 60 steam/sec. However, actual power production is based on the temperature of the steam, not the building itself. This means that using a steam turbine is no more fuel-efficient than using two steam engines. Unless saving space within a large build, it is not necessary to use the more costly turbines for boiler steam.
Power output
Each steam turbine takes a maximum input of 60 units of 500°C steam per second and outputs 5.82MW of electricity; the 5.8MW listed on the tooltip is rounded.
- Heat exchanger heats 15°C water to 500°C steam;
- It takes 0.2 kJ of burner energy to raise 1 water 1°C;
- Steam is consumed by steam turbines at a rate of 60 units per second;
- (500°C - 15°C) × 0.2 kJ × 60 units/s = 5820 kJ/s, or 5.82 MW.
- On the other hand, the calculation for the Boiler-generated steam is: (165°C - 15°C) × 0.2 kJ × 60 units/s = 1800 kJ/s, or 1.8 MW.
History
- 0.18.18:
- Adjusted steam engine and turbine collision boxes so player can walk between two steam engines.
- 0.15.0:
- Introduced