In other languages: Deutsch Français 日本語 한국어 Polski Português, Brasil Русский Українська 简体中文

Steam turbine: Difference between revisions

From Official Factorio Wiki
Jump to navigation Jump to search
Created page with "{{Languages}} {{Stub}} {{:Steam turbine/infobox}} The '''steam turbine''' consumes steam to create electric energy. It is usually used together with heat exchangers an..."
 
Mention 1:10 water:steam conversion ratio, and the relevant heat capacity is steam not water. Also the heat energy does not need to come from burnable fuel (and usually doesn't).
 
(18 intermediate revisions by 12 users not shown)
Line 1: Line 1:
{{Languages}}
{{Languages}}
{{Stub}}
{{:Infobox:Steam turbine}}
{{:Steam turbine/infobox}}
The '''steam turbine''' consumes [[steam]] to create electric energy. It is usually used together with [[heat exchanger]]s and a [[nuclear reactor]] or [[heating tower]]{{SA}}.
The '''steam turbine''' consumes [[steam]] to create electric energy. It is usually used together with [[heat exchanger]]s and a [[nuclear reactor]].
 
While designed for the 500°C steam of a nuclear reactor, turbines can still be connected to [[boiler]]s for use in conventional 165°C steam power. At this mode, the steam turbine acts equal to two separate [[steam engine]]s, producing 1800 kW and consuming 60 steam/sec. However, actual power production is based on the temperature of the steam, not the building itself. This means that using a steam turbine is no more fuel-efficient than using two steam engines. Unless saving space within a large build, it is not necessary to use the more costly turbines for boiler steam.
 
== Power output ==
 
Each steam turbine takes a maximum input of 60 units of 500°C [[steam]] per second and outputs 5.82MW of electricity; the 5.8MW listed on the tooltip is rounded.
 
* [[Heat exchanger]] converts [[water]] to [[steam]] at a 1:10 ratio, and heats it from 15°C to 500°C;
* It takes 0.2 kJ of [[Fuel|heat]] energy to raise 1 steam 1°C;
* Steam is consumed by steam turbines at a rate of 60 units per second;
* (500°C - 15°C) × 0.2 kJ × 60 units/s = 5820 kJ/s, or 5.82 MW.
* On the other hand, the calculation for the Boiler-generated steam is: (165°C - 15°C) × 0.2 kJ × 60 units/s = 1800 kJ/s, or 1.8 MW.


== History ==
== History ==
{{history|0.18.18|
* Adjusted [[steam engine]] and turbine collision boxes so player can walk between two steam engines.}}
{{History|0.15.0|
{{History|0.15.0|
* Introduced}}
* Introduced}}


== See also ==
== See also ==
* [[Nuclear power]]
* [[Power production#Nuclear power|Power production]]
** [[Heat pipe]]
* [[Heat pipe]]
* [https://www.reddit.com/r/factorio/comments/67xgge/nuclear_ratios/ Nuclear ratios]


{{ProductionNav}}
{{ProductionNav}}
{{C|Nuclear power}}
{{C|Energy}}

Latest revision as of 19:44, 16 April 2025

Steam turbine

  • Base game
  •  
  • Space Age mod

Recipe

3
+
50
+
50
+
20
1

Total raw

38
+
50
+
120

Map color

Fluid storage volume

200

Health

300
390 480
570 750

Resistances

Fire: 0/70%

Stack size

10

Rocket capacity

10 (1 stacks)

Dimensions

3×5

Power output

5.82
7.57 9.31
11.06 14.55
MW

Maximum temperature

500 °C

Fluid consumption

60/s
78/s 96/s
114/s 150/s
steam

Mining time

0.3

Prototype type

generator

Internal name

steam-turbine

Required technologies

Produced by

The steam turbine consumes steam to create electric energy. It is usually used together with heat exchangers and a nuclear reactor or heating tower.

While designed for the 500°C steam of a nuclear reactor, turbines can still be connected to boilers for use in conventional 165°C steam power. At this mode, the steam turbine acts equal to two separate steam engines, producing 1800 kW and consuming 60 steam/sec. However, actual power production is based on the temperature of the steam, not the building itself. This means that using a steam turbine is no more fuel-efficient than using two steam engines. Unless saving space within a large build, it is not necessary to use the more costly turbines for boiler steam.

Power output

Each steam turbine takes a maximum input of 60 units of 500°C steam per second and outputs 5.82MW of electricity; the 5.8MW listed on the tooltip is rounded.

  • Heat exchanger converts water to steam at a 1:10 ratio, and heats it from 15°C to 500°C;
  • It takes 0.2 kJ of heat energy to raise 1 steam 1°C;
  • Steam is consumed by steam turbines at a rate of 60 units per second;
  • (500°C - 15°C) × 0.2 kJ × 60 units/s = 5820 kJ/s, or 5.82 MW.
  • On the other hand, the calculation for the Boiler-generated steam is: (165°C - 15°C) × 0.2 kJ × 60 units/s = 1800 kJ/s, or 1.8 MW.

History

  • 0.18.18:
    • Adjusted steam engine and turbine collision boxes so player can walk between two steam engines.

See also