* Steam is consumed by steam turbines at a rate of 60 units of water per second;
* Steam is consumed by steam turbines at a rate of 60 units of water per second;
* (500°C - 15°C) × 0.2 kJ × 60 units = 5820 kW, or 5.82 MW.
* (500°C - 15°C) × 0.2 kJ × 60 units = 5820 kW, or 5.82 MW.
* The calculation for the Boiler-generated steam is: (165°C - 15°C) × 0.2 kJ × 60 units = 1800 kW.
* On the other hand, the calculation for the Boiler-generated steam is: (165°C - 15°C) × 0.2 kJ × 60 units = 1800 kW, or 1.8 MW.


== History ==
== History ==

Revision as of 10:15, 2 March 2019

Steam turbine.png
Steam turbine

Steam turbine entity.png

Recipe

Time.png
3
+
Copper plate.png
50
+
Iron gear wheel.png
50
+
Pipe.png
20
Steam turbine.png
1

Total raw

Time.png
38
+
Copper plate.png
50
+
Iron plate.png
120

Map color

Fluid storage volume

200

Health

Quality normal.png 300
Quality uncommon.png 390 Quality rare.png 480
Quality epic.png 570 Quality legendary.png 750

Resistances

Fire: 0/70%

Stack size

10

Rocket capacity

10 (1 stacks)

Dimensions

3×5

Power output

Quality normal.png 5.82
Quality uncommon.png 7.57 Quality rare.png 9.31
Quality epic.png 11.06 Quality legendary.png 14.55
MW

Maximum temperature

500 °C

Fluid consumption

Quality normal.png 60/s
Quality uncommon.png 78/s Quality rare.png 96/s
Quality epic.png 114/s Quality legendary.png 150/s
steam

Mining time

0.3

Prototype type

generator

Internal name

steam-turbine

Required technologies

Nuclear power (research).png

Produced by

Assembling machine 1.png
Assembling machine 2.png
Assembling machine 3.png
Player.png

The steam turbine consumes steam to create electric energy. It is usually used together with heat exchangers and a nuclear reactor.

While designed for the 500°C steam of a nuclear reactor, turbines can still be connected to boilers for use in conventional 165°C steam power. At this mode, the steam turbine acts equal to two separate steam engines, producing 1800 kW and consuming 60 steam/sec. However, actual power production is based on the temperature of the steam, not the building itself. This means that using a steam turbine is no more fuel-efficient than using two steam engines. Unless saving space within a large build, it is not necessary to use the more costly turbines for boiler steam.

Power output

Each Steam turbine takes a maximum input of 60 units of 500°C steam per second and outputs 5.82MW of electricity; the 5.8MW listed on the tooltip is rounded.

  • Heat exchanger heats 15°C water to 500°C steam;
  • It takes 0.2 kJ of burner energy to raise 1 water 1°C;
  • Steam is consumed by steam turbines at a rate of 60 units of water per second;
  • (500°C - 15°C) × 0.2 kJ × 60 units = 5820 kW, or 5.82 MW.
  • On the other hand, the calculation for the Boiler-generated steam is: (165°C - 15°C) × 0.2 kJ × 60 units = 1800 kW, or 1.8 MW.

History

See also