In other languages: Deutsch Français 日本語 한국어 Nederlands Polski Português, Brasil Русский Українська 简体中文

Heat exchanger: Difference between revisions

From Official Factorio Wiki
Jump to navigation Jump to search
D0sboots (talk | contribs)
Added heat capacity info
Alfonse (talk | contribs)
m Space Age annotation.
 
(20 intermediate revisions by 10 users not shown)
Line 1: Line 1:
{{Languages}}
{{Languages}}{{:Infobox:Heat exchanger}}
{{Stub}}
The '''heat exchanger''' exchanges heat between a heat connection (normally from a [[heat pipe]] leading to a [[nuclear reactor]] or [[heating tower]]{{SA}}) and [[water]] to produce [[steam]].
{{:Heat exchanger/infobox}}


The '''heat exchanger''' exchanges heat between a heat source and a fluid. It is usually used together with a [[nuclear reactor]] and [[steam turbine]]s.
Heat exchangers produce ~103 steam with a temperature of 500°C every second.  


Heat Exchangers will not produce steam until they reach 500°C.
Heat exchangers will not produce steam until they reach 500°C. The steam produced is exactly 500°C hot, even if the exchanger is hotter. Heat exchangers have a heat capacity of 1 MJ/°C. Thus, they can buffer 500 MJ of heat energy across their working range of 500°C to 1000°C, and require 485 MJ of energy to warm up from 15°C to 500°C when initially placed.  


Heat Exchangers have a heat capacity of 1 MJ/C. Thus, they can buffer 500 MJ of heat energy across their working range of 500C to 1000C, and require 485 MJ of energy to warm up from 15C to 500C when initially placed.
== Calculating steam production rate ==
 
Heat exchangers produce 103 steam/second. This can be calculated by relying on [[steam turbine]] data: A steam turbine consumes 60 steam/second and produces 5.82MW (assuming 500°C steam). This means a single unit of 500°C steam has <code>5.82MW / (60/s) = 0.097 MJ</code> of energy. A heat exchanger produces 10 MJ a second, therefore it produces <code>10MJ / 0.097MJ = 103.0927835</code> steam per second.
 
The steam production rate can also be calculated using the energy consumption: 1 heat exchanger consumes 10MW, so it's putting 10MJ of energy into heating water/steam per second. To heat up 1 unit of water 1 degree, 200 joules are needed,<!--i.e. the specific heat capacity of water is 200 J/(unit.°C) - Factorio doesn't account for latent heat of vaporization--> so the heat exchanger is heating up water by 50,000 unit-°C<!--not simply "°C" - the dimensions are not correct for that unit--> in total. We observe that this heating results in a temperature increase from 15°C to 500°C, so an increase of 485°C. So the 50,000 unit-°C is divided among 103 units of steam per second, since <code>50,000 / 485 = 103.09</code>. Since steam is produced from water in a 10:1 ratio, this also means that 10.3 units of water are consumed per second.


== History ==
== History ==
{{History|2.0.7|
* 1 Water will now produce 10 Steam in boilers/heat exchangers.}}
{{History|0.17.67|
* Heat pipes (also in reactors and heat exchangers) glow with high temperatures.}}
{{History|0.15.0|
{{History|0.15.0|
* Introduced}}
* Introduced
* Doubled the heat capacity of water from 0.1kJ per degree per liter to 0.2kJ}}


== See also ==
== See also ==
* [[Nuclear power]]
* [[Power production#Nuclear power|Nuclear power]]
** [[Heat pipe]]
* [[Steam turbine]]
 
* [[Nuclear reactor]]
* [[Heating tower]] {{SA}}
* [[Heat pipe]]


{{ProductionNav}}
{{ProductionNav}}
{{C|Nuclear power}}
{{C|Energy}}

Latest revision as of 23:25, 15 February 2025

Heat exchanger

Recipe

3
+
100
+
10
+
10
1

Total raw

8
+
100
+
10
+
10

Map color

Fluid storage volume

Input: 200
Output: 200

Health

200
260 320
380 500

Resistances

Explosion: 0/30%
Fire: 0/90%
Impact: 0/30%

Stack size

50

Rocket capacity

25 (0.5 stacks)

Dimensions

2×3

Energy consumption

10
13 16
19 25
MW (heat)

Heat output

103/s
134/s 165/s
196/s 258/s
steam

Maximum temperature

1000 °C

Fluid consumption

10.3/s
13.4/s 16.5/s
19.6/s 25.8/s
water

Mining time

0.1

Prototype type

boiler

Internal name

heat-exchanger

Required technologies

Produced by

The heat exchanger exchanges heat between a heat connection (normally from a heat pipe leading to a nuclear reactor or heating tower) and water to produce steam.

Heat exchangers produce ~103 steam with a temperature of 500°C every second.

Heat exchangers will not produce steam until they reach 500°C. The steam produced is exactly 500°C hot, even if the exchanger is hotter. Heat exchangers have a heat capacity of 1 MJ/°C. Thus, they can buffer 500 MJ of heat energy across their working range of 500°C to 1000°C, and require 485 MJ of energy to warm up from 15°C to 500°C when initially placed.

Calculating steam production rate

Heat exchangers produce 103 steam/second. This can be calculated by relying on steam turbine data: A steam turbine consumes 60 steam/second and produces 5.82MW (assuming 500°C steam). This means a single unit of 500°C steam has 5.82MW / (60/s) = 0.097 MJ of energy. A heat exchanger produces 10 MJ a second, therefore it produces 10MJ / 0.097MJ = 103.0927835 steam per second.

The steam production rate can also be calculated using the energy consumption: 1 heat exchanger consumes 10MW, so it's putting 10MJ of energy into heating water/steam per second. To heat up 1 unit of water 1 degree, 200 joules are needed, so the heat exchanger is heating up water by 50,000 unit-°C in total. We observe that this heating results in a temperature increase from 15°C to 500°C, so an increase of 485°C. So the 50,000 unit-°C is divided among 103 units of steam per second, since 50,000 / 485 = 103.09. Since steam is produced from water in a 10:1 ratio, this also means that 10.3 units of water are consumed per second.

History

  • 2.0.7:
    • 1 Water will now produce 10 Steam in boilers/heat exchangers.
  • 0.17.67:
    • Heat pipes (also in reactors and heat exchangers) glow with high temperatures.
  • 0.15.0:
    • Introduced
    • Doubled the heat capacity of water from 0.1kJ per degree per liter to 0.2kJ

See also