Talk:Inserters: Difference between revisions
(Created page with " [http://kovarex.com/forum/viewtopic.php?f=7&t=22#p71] Removed. But eventually helpful. ~~~~") |
(→Inserter speed: new section) |
||
Line 2: | Line 2: | ||
Removed. But eventually helpful. [[User:Ssilk|Ssilk]] ([[User talk:Ssilk|talk]]) 02:45, 31 December 2013 (CET) | Removed. But eventually helpful. [[User:Ssilk|Ssilk]] ([[User talk:Ssilk|talk]]) 02:45, 31 December 2013 (CET) | ||
== Inserter speed == | |||
I updated this wiki to show ticks per turn in the inserter speed section. My results seem to clash with the previous information about rotation speed (102 ticks = 1.7 seconds, there is a discrepancy between the rotation time of burner inserters most notably). The experiment I performed was done on vanilla factorio 0.14.22. I used two steel chests with varying inserters for each experiment. The inserters were fully powered at all times. The first chest is wired to a combinator which tests for any items in the chest, and outputs 1 signal X. This signal is added to a tallying arithmetic combinator. This arithmetic combinator is wired to itself, and outputs T + X. The value of T at setup is 0. I begin this experiment by placing large stacks of items into the first chest. I place only 201 transfers worth of material into the chest. This will stop the timer as soon as the last item is removed, which occurs after 200 transfers. With this setup I obtained the results as I have reported them. The timer always stopped on a multiple of 200, indicating that the number of ticks per full turn is an integer number. This is why I decided to add a separate column for this value. I may in the future update the other rotation speed metrics to match my results. --[[User:Reububble|Reububble]] ([[User talk:Reububble|talk]]) 18:19, 8 March 2017 (UTC) |
Revision as of 18:19, 8 March 2017
[1]
Removed. But eventually helpful. Ssilk (talk) 02:45, 31 December 2013 (CET)
Inserter speed
I updated this wiki to show ticks per turn in the inserter speed section. My results seem to clash with the previous information about rotation speed (102 ticks = 1.7 seconds, there is a discrepancy between the rotation time of burner inserters most notably). The experiment I performed was done on vanilla factorio 0.14.22. I used two steel chests with varying inserters for each experiment. The inserters were fully powered at all times. The first chest is wired to a combinator which tests for any items in the chest, and outputs 1 signal X. This signal is added to a tallying arithmetic combinator. This arithmetic combinator is wired to itself, and outputs T + X. The value of T at setup is 0. I begin this experiment by placing large stacks of items into the first chest. I place only 201 transfers worth of material into the chest. This will stop the timer as soon as the last item is removed, which occurs after 200 transfers. With this setup I obtained the results as I have reported them. The timer always stopped on a multiple of 200, indicating that the number of ticks per full turn is an integer number. This is why I decided to add a separate column for this value. I may in the future update the other rotation speed metrics to match my results. --Reububble (talk) 18:19, 8 March 2017 (UTC)