Accumulator: Difference between revisions
Jump to navigation
Jump to search
m (corrected units) |
(Updated recipe & description for 0.9.8. Added link to auto-shutoff.) |
||
Line 1: | Line 1: | ||
The [[Basic accumulator]] stores a limited amount of energy when available production exceeds demand, and releases it in the opposite case. The basic accumulator stores up to 5 MJ of energy. Charge/Discharge rate is 300 kW maximum. | |||
{| class="wikitable" | {| class="wikitable" | ||
| '''Recipe:''' || | | '''Recipe:''' || {{icon|iron-plate|2|iron_plate}} + {{icon|battery|5|Battery}} + {{icon|time icon|0.5|time}} => {{icon|electric-energy-acumulators|1|electric network#Basic accumulator}} | ||
|- | |- | ||
| '''Total raw:''' || {{icon|copper-plate| | | '''Total raw:''' || {{icon|copper-plate|5|copper_plate}} {{icon|iron-plate|7|iron_plate}} {{icon|sulfuric-acid|10|sulfuric_acid}} | ||
|- | |- | ||
| '''Maximum capacity:''' || 5 MJ | | '''Maximum capacity:''' || 5 MJ | ||
Line 12: | Line 12: | ||
| '''Req. Technology:''' || {{imagelink|electric-energy-acumulators|Electric energy accumulators}} |- | | '''Req. Technology:''' || {{imagelink|electric-energy-acumulators|Electric energy accumulators}} |- | ||
|} | |} | ||
See [[Power_Production#How_to_switch_off_steam_engines_in_the_night.2C_when_enough_accumulator_capacity_is_available.3F|How to switch off steam engines in the night, when enough accumulator capacity is available?]] | |||
* When discharged above maximum speed by multiple unconnected poles, will distribute energy unequally (some may get 100% demand, others 0%) | * When discharged above maximum speed by multiple unconnected poles, will distribute energy unequally (some may get 100% demand, others 0%) |
Revision as of 07:25, 19 May 2014
The Basic accumulator stores a limited amount of energy when available production exceeds demand, and releases it in the opposite case. The basic accumulator stores up to 5 MJ of energy. Charge/Discharge rate is 300 kW maximum.
Recipe: | + + => |
Total raw: | |
Maximum capacity: | 5 MJ |
Charge/discharge rate: | 300 kW |
Req. Technology: | Electric energy accumulators |- |
See How to switch off steam engines in the night, when enough accumulator capacity is available?
- When discharged above maximum speed by multiple unconnected poles, will distribute energy unequally (some may get 100% demand, others 0%)
- May be used to provide limited amount of power (multiples of maximum charge rate) to a section of the grid
- Produces light when charging and discharging