Revision as of 19:12, 14 August 2017

Steam turbine.png
Steam turbine

Steam turbine entity.png

Recipe

Time.png
3
+
Copper plate.png
50
+
Iron gear wheel.png
50
+
Pipe.png
20
Steam turbine.png
1

Total raw

Time.png
38
+
Copper plate.png
50
+
Iron plate.png
120

Recipe

Time.png
3
+
Copper plate.png
50
+
Iron gear wheel.png
50
+
Pipe.png
20
Steam turbine.png
1

Total raw

Time.png
38
+
Copper plate.png
50
+
Iron plate.png
240

Map color

Fluid storage volume

200

Health

300

Resistances

Fire: 0/70%

Stack size

10

Dimensions

3×5

Power output

5.82 MW

Maximum temperature

500 °C

Fluid consumption

60/s

Mining time

0.3

Prototype type

generator

Internal name

steam-turbine

Required technologies

Nuclear power (research).png

Produced by

Assembling machine 1.png
Assembling machine 2.png
Assembling machine 3.png
Player.png

The steam turbine consumes steam to create electric energy. It is usually used together with heat exchangers and a nuclear reactor.

While designed for the 500°C steam of a nuclear reactor, turbines can still be connected to boilers for use in conventional 165°C steam power, but the actual power production is based on the temperature of the steam, not the building itself. Unfortunately, this means that using a steam turbine is no more fuel-efficient than using a steam engine, so it's generally not recommended to use the much more expensive turbines with boiler steam. To its credit, the turbine does have double the throughput of a steam engine (it uses 60 steam and outputs 1.8MW of power) so it can still be useful to save space, especially in large power systems.

Power output

Each Steam turbine takes a maximum input of 60 units of 500°C steam per second and outputs 5.82MW of electricity; the 5.8MW listed on the tooltip is rounded.

  • Heat exchanger heats 15°C water to 500°C steam;
  • It takes 0.2kJ of burner energy to raise 1 water 1°C;
  • Steam is consumed by steam turbines at a rate of 60 water/s;
  • (500 - 15) × 0.2 × 60 = 5820kW, or 5.82MW.

History